Welcome to the official website of Guanghui Cable Co., Ltd.!
High- and low-voltage power cables
Description
- Product Description
-
High voltage rubber sheathed flexible cable model reference:
Partial reference cable models: YJV3 * 1.5+1 * 1, YJV3 * 2.5+1 * 1.5, YJV3 * 4+1 * 2.5, YJV3 * 6+1 * 4 cross-linked polyethylene insulated power cables, YJV3*10+1*6,YJV3*16+1*10,YJV3*25+1*16,YJV3*35+1*16,YJV3*50+1*25,YJV3*70+1*35,YJV3*95+1*50 YJV3*120+1*70 YJV3*150+1*70 YJV3*185+1*95 YJV3*240+1*120,YJV3*300+1*150 YCW3*4+2*2.5 Rubber sheathed flexible cable rubber wire 450-750 VYCW33*10+2*6 450-750VYCW3*16+2*CW3*25+2*10450-750VYCW3*35+2*10450-750VYCW3*50+2*16450-750VYCW3*7450-750VYCW3*120+2*35450-750VYCW3*150+2*50450-750VYCW3*185+2*50450-750VYCW3*240+2*70450-750VYCW3*300+2*95 450-750VYCW3*400+2*95 Rubber sheathed flexible cable rubber wire 450-750V
The derivative/new products of wires and cables are mainly produced by using new materials, special materials, changing product structures, increasing process requirements, or combining different varieties of products due to different application scenarios, application requirements, equipment convenience, and requirements for reducing equipment costs. Using different materials such as flame-retardant high-voltage flexible cables, low smoke halogen-free/low smoke low halogen cables, anti termite, anti mouse cables, oil/cold/temperature resistant cables, etc. to change the product structure, such as fire-resistant cables, etc. to improve process requirements, such as medical cables, etc. Combination products such as OPGW, etc
Product model features and usage:
This product is suitable for automatic control systems, computer distributed control systems, automation control systems as control lines, and electronic computer cables for testing instruments and meters in industries such as power, metallurgy, petrochemicals, etc., where the AC U0/U is 300/500V 0.6-1KV 6/10KV 8.7/10KV 26 * 35KV.
Product execution standard: Q/HL002-2002 (equivalent to British BS5308 standard) Flame retardant performance test executed GB12666-90 standard
Usage characteristics
1. Rated AC voltage: U0/U 300/500kV
2. Maximum operating temperature: Polyethylene insulation not exceeding 70 ℃, low smoke halogen-free flame-retardant polyolefin at 70 ℃, low smoke halogen-free flame-retardant cross-linked polyolefin at 90 ℃ and 125 ℃
3. Minimum ambient temperature: PVC sheath: fixed installation -40 ℃, non fixed installation -15 ℃
4. The temperature for cable installation and laying should not be lower than 0 ℃.
5. Allowable bending radius for cables: The minimum allowable bending radius for non armored cables is 6 times the outer diameter of the cable, and the minimum allowable bending radius for copper tape shielded or steel tape armored cables is 12 times the outer diameter of the cable
Purpose:
Used for cables with high anti-interference performance requirements, as well as cables for testing instruments and instrument connection lines with high anti-interference performance, soft copper core high voltage cables, 10kV high voltage soft cables, 3.6/6kV manufacturers and prices
Our factory has been producing and supplying UGF cables, UgFP cables, and UGEFP cables for a long time
Rubber sheathed high-voltage flexible cable (enterprise standard cable)
High voltage rubber sheathed flexible cable model: UGF cable UgFP cable UGEFP cable
Rubber sheathed high-voltage flexible cable model and name:
UG-3.6/6KV cable UG6/10KV cable
UGF-3.6/6KV cable UGF6/10KV cable
UGFP3.6/6KV cable UGFP6/10KV cable
UGEFP3.6/6KV cable UGEFP6/10KV cable
Execution standard: JB1307-73 (Enterprise Standard)
Purpose: AC rated voltage of 6kV and below for mobile power distribution equipment and mining machinery; Lifting and transportation machinery, etc.
Usage characteristics: The rated voltage of the cable is 6kV;
The long-term operating temperature of the cable is+65 ℃.
The minimum bending radius of a cable is 6 times the diameter of the cable.
The insulation resistance between finished cable cores, converted to a length of 1km and a temperature of 20 ℃, should not be less than 100 megaohms.
The main cores of the finished cable and between the main cores and the grounding wire should be able to withstand an AC voltage test of 50 Hz 15000 volts for 5 minutes without breakdown.
FAQs
Which regions are covered by the scope of cooperative supply
How is the company's R&D and technical capability
Can the product meet special requirements such as fire prevention and environmental protection
Where are the production bases and service outlets distributed
How is the company's credit reputation
What authoritative qualifications and honors does the enterprise possess
High- and low-voltage power cables
OUR SERVICE
We offers a wealth of product support resources, including a range of technical and downloadable product manuals to product certifications.
Application Contact Us